| News Headlines |
Thu. Aug 12th 2010 For Sale
The Maynard
Fire Department would
like to announce that
Engine 2 is now up for
sale. Engine 2 is a
1984 Saul...
Read more »
|
Tue. Jun 29th 2010 ATTN: Help Needed
Engine 3 is on its way to
Marcy and will be at
Station 2 by Tuesday
evening (29th). Help will
be needed to get the
truck into...
Read more »
|
Mon. Jun 7th 2010 New Engine 3
Heres the newest pictures
of Engine 3. Were
are set to take delivery
in 2 weeks.
Read more »
|
| Apparatus Gallery |  |
|
Fire Glossary Print this page
Page: |
1 |
2 |
Call Fighter Call firefighters respond as needed on a part time basis to all types of emergencies. Call firefighters train with their local engine companies in their districts. Call firefighters are utilized in three different ways. First Responder call firefighter units are those units that are staffed entirely by paid call firefighters. These firefighters respond to all emergency incidents within their jurisdictional areas and are supported by full-time companies from adjoining jurisdictions. "Supplemental" call firefighter units are those units that staff a second engine company from a station that is also staffed by a full-time company. These units respond to all multi-unit responses in their district and cover the station when the career companies are committed. "Augmentation" call firefighters are assigned to an existing career company and respond directly to the scene to augment that company's staffing.
Cellar fire Cellar fires are difficult to attack directly because firefighters have to pass through the hot gasses and smoke accumulated on the cellar's ceiling to gain access to the cellar space. Cellars typically do not have good emergency egress points, adding to the danger.
Cellar pipe Cellar Nozzle. A distributing type nozzle that is inserted through an opening in the floor and into the space below, typically a basement or cellar. The nozzle directs a broken stream horizontally, either extinguishing or controlling the fire enough to allow a direct attack to be safely made. Can also be used on top of other containers.
CFA 3-Thread A type of coupling used by the CFA, it is used mainly on the australian 64mm hose, it provides a very secure coupling, obviously the threading of the coupling is repeated 3 times, it is non-hemaphoradite.
Charged line Fire hose under pressure from the pump at the engine.
Check valve See backflow preventer
Chimney fire Fast and intense fire in a chimney flue in which accumulated creosote and other combustion byproducts ignite.
Class A, B, C, D, K Classes of fire extinguisher and corresponding type of fire they extinguish.
Closed area An area in which specified activities or entry are temporarily restricted to reduce risk of human-caused fires.
Closed-circuit SCBA See SCBA.
Closet hook Pike pole under 5 ft long
Closet ladder See Attic ladder.
Closure Legal restriction, but not necessarily elimination, of specified activities such as smoking, camping, or entry that might cause fires in a given area.
CO2 extinguisher Fire extinguisher that releases carbon dioxide gas to smother and cool a fire, such as a flammable liquid.
Cockloft Structural space above ceiling and below rafters, often connecting adjacent occupancies and permitting fire to spread laterally, often unseen.
Cold trailing A method of controlling a partly dead fire edge by carefully inspecting and feeling with the hand for heat to detect any fire, digging out every live spot, and trenching any live edge.
Collapse zone The area around a structure that would contain debris if the building were to collapse.
Combination nozzle A low pressure Fog Nozzle (usually 120 to 150 lbf/inē or 820 to 1030 [[kilopascal|kPa)) that can be adjusted to produce a near straight stream. Also commonly referred to as a Taskforce Tip (TFT).
Company Two or more firefighters organized as a team, led by a fire officer, and equipped to perform certain operational functions. Compare with platoon and unit.
Compartment Fire An Isolated" fire or a fire which is "boxed in" or "closed off" from the rest of the structure. An example of this is a fire in a room where all the windows and doors are closed preventing the fire from spreading to other rooms.
|
|
| Recent Calls |
Sun. Apr 11th 2010 Structure Fire
At 0132hrs on Sunday, the
Maynard Fire Department
was dispatched to a
possible structure fire
in an abandoned building
on Riv...
Read more »
|
Tue. Apr 6th 2010 Easter Brush Fire
MARCY —
A
brush fire spread Sunday
over roughly an acre of
land near Edic Road,
burning up dry grass and
small...
Read more »
|
Tue. Mar 23rd 2010 Maynard responds to Stage Road MVA
On Monday, March 22nd at
4:30pm, the Maynard Fire
Department was dispatched
to a Motor Vehicle
Accident on Stage Road.
Initia...
Read more »
|
| Picture Gallery |  |
| 2010 Call Volume |
| |
Fire |
EMS |
| January |
22 |
25 |
| February |
20 |
13 |
| March |
17 |
13 |
| April |
14 |
23 |
| May |
18 |
11 |
| June |
11 |
12 |
| July |
27 |
17 |
| August |
|
|
| September |
|
|
| October |
|
|
| November |
|
|
| December |
|
|
| Total |
129 | 114 |
View Call Volume History
|
|